Dp-v1 parameter data channel (profidrive profile), Communication manual 8400 protec profibus – Lenze E84Dxxxx User Manual

Page 45

Advertising
background image

Communication manual 8400 protec PROFIBUS

Parameter data transfer

DP-V1 parameter data channel (PROFIdrive profile)

45

L

EDS84DPBUS EN 2.0 - 09/2010

8.3

DP-V1 parameter data channel (PROFIdrive profile)

Data communication with the PROFIBUS DP-V0 is characterised by cyclic diagnostics and

cyclic process data and parameter data transfer.
An optional service extension is the acyclic parameter data transfer of the PROFIBUS DP-

V1. All standard services under PROFIBUS DP-V0 still maintain their unrestricted validity.
PROFIBUS DP-V0 and PROFIBUS DP-V1 can be operated simultaneously in the same

network. This enables the step-by-step extension or retrofitting of a system.
The services of PROFIBUS DP-V1 can be used by the class 1 master (PLC) and class 2 master

(diagnostics master etc.).
The integration of the acyclic service into the fixed bus cycle depends on the corresponding

configuration of the class 1 master:

With configuration, a time slot is reserved.

Without configuration the acyclic service is appended when a class 2 master acyclically

accesses a DP-V1 slave.

Features

Address for parameter number and subindex with a width of 16 bits each.

Several parameter requests can be united to one request (multi-parameter request).

There is always only one parameter request in process (no pipelining).

A parameter request/response must fit into a data block (max. 240 bytes). Requests/

responses cannot be split into several data blocks.

No spontaneous messages are transferred.

Only acyclic parameter requests exist.

Profile-specific parameters can be read independently of the slave status.

Advertising