6 error codes, Error codes, Error codes ( 42) – Lenze E84Dxxxx User Manual

Page 42: Communication manual 8400 protec profibus

Advertising
background image

EDS84DPBUS EN 2.0 - 09/2010

L

42

Communication manual 8400 protec PROFIBUS

Parameter data transfer

DP-V0 parameter data channel (DRIVECOM profile)

8.2.6

Error codes

The following error messages can occur:

Byte 8

Byte 7

Byte 6

Byte 5

Meaning

Error 1

Error 2

Error 3

Error 4

0x06

0x03

0x00

0x00

No right to access

0x06

0x05

0x11

Invalid subindex

0x06

0x05

0x12

Data length too big

0x06

0x05

0x13

Data length too small

0x06

0x07

0x00

Object does not exist

0x06

0x08

0x00

Data types do not comply with each other

0x08

0x00

0x00

Job cannot be executed

0x08

0x00

0x20

Job cannot be executed at the moment

0x08

0x00

0x22

Request cannot be executed because of device status / parameter

can only be changed with inhibited controller

0x08

0x00

0x30

Out of value range

0x08

0x00

0x31

Value of the parameter is too high

0x08

0x00

0x32

Value of the parameter is too low

0x08

0x00

0x80

Hardware error

Advertising