Communication manual 8400 protec PROFIBUS
Parameter data transfer
DP-V1 parameter data channel (PROFIdrive profile)
61
L
EDS84DPBUS EN 2.0 - 09/2010
Parameter response after faultless write request
Parameter response after read error
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identification
Axis
Number of indices
0xXX
0x02
0x00
0x01
(mirrored)
Parameter written
(mirrored)
1 index
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identification
Axis
Number of indices
0xXX
0x82
0x00
0x01
(mirrored)
Parameter not written
(mirrored)
1 index
Byte 5
Byte 6
Format
Number of values
0x44
0x01
Fault
Error code without additional
information
Byte 7
Byte 8
Error code
High byte
Low byte