C13899 | station address, C13900 | firmware product type, C13901 | firmware compilation date – Lenze E84Dxxxx User Manual

Page 85: C13902 | firmware version, C13920 | display: dip switch setting, C13920, C13899, Communication manual 8400 protec profibus

Advertising
background image

Communication manual 8400 protec PROFIBUS

Parameter reference

Parameters relevant for the communication

85

L

EDS84DPBUS EN 2.0 - 09/2010

C13899

C13900

C13901

C13902

C13920

Parameter | Name:

C13899 | Station address

Data type: UNSIGNED_8

Index: 10676

d

= 29B4

h

Optional setting of the station address (instead of setting via DIP switches 1 ... 64)

• The station address set here only becomes effective if the DIP switches 1 ... 64 have been set to OFF prior to mains

switching.

• The active station address is displayed under

C13864

.

Note!

A change in the station address will not be effective until the "Save parameter set" command was executed and

another mains switching for the module / drive was performed.



Setting the station address ( 24)

Setting range

(min. value | unit | max. value)

Lenze setting

3

126 3

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C13900 | Firmware product type

Data type: VISIBLE_STRING

Index: 10675

d

= 29B3

h

Display of the product type (string with a length of 8 bytes)

• The following identification code is displayed: "E84DFYPM".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13901 | Firmware compilation date

Data type: VISIBLE_STRING

Index: 10674

d

= 29B2

h

Display of the compilation date of the firmware (string with a length of 20 bytes)

• The date ("MMM DD YYYY") and time ("hh:mm:ss") are displayed, e.g. "Mar 21 2005 12:31:21".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13902 | Firmware version

Data type: VISIBLE_STRING

Index: 10673

d

= 29B1

h

Display of the firmware version (string with a length of 5 bytes)

• An identification code is displayed, e.g. "01.00.00.00".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13920 | Display: DIP switch setting

Data type: UNSIGNED_8

Index: 10655

d

= 299F

h

Display of the current DIP switch setting

• The displayed value corresponds to the sum of the individual DIP switch values 1 ... 64.

• The active station address is displayed under

C13864

.



Setting the station address ( 24)

Display area

(min. value | unit | max. value)

0

255

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Advertising