background image

Communication manual 8400 protec PROFIBUS

Parameter reference

Implemented PROFIdrive objects (DP-V1)

89

L

EDS84DPBUS EN 2.0 - 09/2010

I-974

Index | Name:

0x974 | Maximum time per DPV1 parameter access

Data type: U16

Display of access statistics
Subindex

Display

Info

0x974/0

240 bytes

Maximum block length

0x974/1

40

Maximum number of parameter accesses

0x974/2

0

Maximum time per access

;

Read access … Write access