C13861 | bus status, C13862 | bus counter, C13863 | baud rate – Lenze E84Dxxxx User Manual

Page 81: Communication manual 8400 protec profibus

Advertising
background image

Communication manual 8400 protec PROFIBUS

Parameter reference

Parameters relevant for the communication

81

L

EDS84DPBUS EN 2.0 - 09/2010

C13861

C13862

C13863

Parameter | Name:

C13861 | Bus status

Data type: UNSIGNED_16

Index: 10714

d

= 29DA

h

Bit coded display of the current bus status.



Querying the current bus status ( 70)

Display area

(min. value | unit | max. value)

0

65535

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13862 | Bus counter

Data type: UNSIGNED_16

Index: 10713

d

= 29D9

h

When the maximum count value of 65535 is reached, the counter starts again with 0.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13862/1

Data cycles per second

C13862/2

Total data cycles

C13862/3

Total parameterisation events

C13862/4

Total configuration events

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13863 | Baud rate

Data type: UNSIGNED_8

Index: 10712

d

= 29D8

h

Display of baud rate
Selection list

(read only)

Info

0 12.00 Mbps
1 6.00 Mbps
2 3.00 Mbps
3 1.50 Mbps
4 500.00 kbps
5 187.50 kbps
6 93.75 kbps
7 45.45 kbps
8 19.20 kbps
9 9.60 kbps

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT