6 response after a write error, Communication manual 8400 protec profibus – Lenze E84Dxxxx User Manual

Page 55

Advertising
background image

Communication manual 8400 protec PROFIBUS

Parameter data transfer

DP-V1 parameter data channel (PROFIdrive profile)

55

L

EDS84DPBUS EN 2.0 - 09/2010

8.3.3.6

Response after a write error

Response head

Parameter format

Error code

Byte 1

Byte 2

Byte 3

Byte 4

Request reference

(mirrored)

Response identification

Axis

(mirrored)

Number of indices

Field

Data type

Values

Request reference

U8

Mirrored value of the parameter request

Response identification

U8

0x82: Parameter not written

• The data in the bytes 7 + 8 must be interpreted as

error code.

Axis

U8

0x00 or 0x01

Number of indices

U8

0x"n" (n = number of parameters addressed)

Byte 5

Byte 6

Format

Number of values

Field

Data type

Values

Format

U8

0x44: Error

Number of values

U8

0x01: Error code without additional information

0x02: Error code with additional information

Byte 7

Byte 8

Byte 9

Byte 10

Error code

Additional information

(if available)

High byte

Low byte

High byte

Low byte

Field

Data type

Values

Error code

U16

0x0000 .... 0xFFFF



Error codes ( 56)

Additional information

(if available)

U16

Advertising