Write Single Block

The Write Single Block command writes a single block of user data to an
RFID tag.

Set the following values in the output image table:

a. xx:O.Channel[0].Command = 10
b. xx:O.Channel[0].Address = starting address to write
c. xx:O.Channel[0].BlockSize = 0, 4, or 8
d. xx:O.Channel[0].Data[0…112] = data to write
e. xx:O.Channel[0].Length = 0, 4, or 8
f. xx:O.Channel[0].BlockSize = 0, 4, or 8
g. xx:O.Channel[0].Reset = 0
h. xx:O.Channel[0].Timeout = 0
i. xx:O.Channel[0].UIDLow = 0 (or UIDLow)
j. xx:O.Channel[0].UIDHi = 0 (or UIDHi)

If UIDLow and UIDHi are set to 0, this command will operate on the first tag in
the field. Specify a UUID in xx:O.Channel[0].UIDLow and
xx:O.Channel[0].UIDHi to perform the command on a specific tag.

The Length and Block Size fields are used to specify the number of bytes/block
of the tag. Valid values are:

0 = 4 bytes/block

4 = 4 bytes/block

8 = 8 bytes/block

Typically, ISO15693 tags have a block size of 4 bytes/block, and FRAM tags have
a block size of 8 bytes/block.