Transceiver Connection
The M12 QD female connector for the transceivers is shown below. Pin 5 is the
cable shield connection and is connected only at the block to functional earth
(FE).
Digital Input Connection
The female M12 QD input connector is shown below.
Digital Output Connection
The female M12 QD output connector is shown below.
Pin
Function
1
24V DC power
2
Data +
3
24V common
4
Data -
5
Shield/FE
Pin
Function
1
24V DC power
2
Not used
3
24V common
4
Digital input
5
Shield/FE
Pin
Function
1
Not used
2
Not used
3
24V common
4
Digital output
5
Shield/FE
4
3
1
2
5
4
3
1
2
5
4
3
1
2
5
Advertising