Chapter 12

RFID Tag Speed

recommended delay time value into the Timeout field prior to initiating a
continuous read.

During Teach Mode, the ContReadMode and Busy bit will be set to true.

Teach mode can canceled by issuing a channel reset (reset bit in the output image
word set to 1).

Command Structure

a. xx:O.Channel[0].Reset =0
b. xx:O.Channel[0].BlockSize =Bytes per Block in the tag
c. xx:O.Channel[0].Command = 8
d. xx:O.Channel[0].Address = Starting Block
e. xx:O.Channel[0].Length = Number of Blocks
f. xx:O.Channel[0].Timeout = 0
g. xx:O.Channel[0].UIDLow = 0
h. xx:O.Channel[0].UIDHi = 0
i. xx:O.Channel[0].Data[0] = Mode x
j. xx:O.Channel[0].Data[1] = Option Flag