Chapter 2

RFID Components

LED Indicators

When the indicator is flashing, all flashes are 0.25 s ON and 0.25 s OFF.

This block has the seven different indicators.

Figure 3 - LED Indicators

Table 2 - LED Indicators

LED Name

LED State

Indicates

Link1 and
Link2

Off

No link

Green

100 Mbps

Flashing green

100 Mbps/active

Yellow

10 Mbps

Flashing yellow

10 Mbps/active

MOD (Module)

Off

There is no power applied to the block.

Flashing red/
green

Device in self-test

Green

The block is operating in a normal condition.

Flashing green

Standby. The device is not communicating with the interface block. Normal state
when only power has been applied to the transceiver.

Flashing red

Recoverable fault. Most often occurs when data is corrupted between interface
block and transceiver. CRC failures etc. Recommended solution is to remove
electrical noise near cabling or reduce baud rate between transceiver and
interface block.

Red

The transceiver has an unrecoverable fault; may need replacing.