Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011

145

CIP Information Appendix B

Discrete Input Point Object
Class Code 0x0008

The following class attributes are currently supported for the Discrete Input
Point Object:

Two instances of the Discrete Input Point Object are supported. All instances
contain the following attributes.

The following common services will be implemented for the Discrete Input Point
Object.

To obtain the status of an input point (ON or OFF), configure a CIP message as
shown below:

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

0xC7

2

2

Get

Max Instance

UINT

4

Attribute ID

Access Rule

Name

Data Type

Value

3

Get

Value

BOOL

0 = OFF, 1 = ON

5

FilterOffOn

0xC7

0 = No Delay
1000 = 1 ms
2000 = 2 ms
4000 = 4 ms
8000 = 8 ms
16000 = 16 ms

6

FilterOnOff

0xC7

0 = No Delay
1000 = 1 ms
2000 = 2 ms
4000 = 4 ms
8000 = 8 ms
16000 = 16 ms

Service Code

Implemented for:

Service Name

Class

Instance

0x0E

Yes

Yes

Get_Attribute_Single

0x10

No

Yes

Set_Attribute_Single