Rockwell Automation 56RF RFID System User Manual User Manual
Page 132
![background image](/manuals/577010/132/background.png)
132
Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011
Appendix B CIP Information
Identity Object Class Code
0x0001
This Identity Object provides identification of and general information about the
device.
Instance 1 of the Identity Object will contain the following attributes:
The following common services will be implemented for Instance 1.
Accessing the Identity Object will require the creation of a Message Instruction
(MSG) to be configured as a CIP Generic type.
Service Code: 1- Get Attribute All
Class: 1 - Identity Object
Instance: 1 - First instance
Attribute: 1 - First attribute
Destination: CIP_Data - a SINT[100] array to hold the data
Attribute ID
Access
Rule
Name
Data Type
Value
1
Get
Vendor
UINT
1
2
Get
Device Type
UINT
139
3
Get
Product Code
UINT
4,5, or 6
4
Get
Revision
Major Revision
Minor Revision
Structure of:
USINT
USINT
The initial release is Major Rev. 1,
Minor Rev. 1.
5
Get
Status
WORD
Refer to Device Status
(CIP_Data[8]-[9]) table below.
6
Get
Serial Number
UDINT
Unique number for each device
7
Get
Product Name
String Length
ASCII String
Structure of:
USINT
STRING
Product Code specific
Service Code
Implemented for:
Service Name
Class
Instance
0x01
Yes
Yes
Get_Attributes_All
0x05
No
Yes
Reset
0x0E
Yes
Yes
Get_Attributes_Single