Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011

15

RFID Components

Chapter 2

Transceivers

LED Indicators

Figure 4 - Indicators

NET (Network)

Off

There is no power or no IP address.

Flashing red/
green

Device in self-test

Green

The block is operating in a normal condition.

Flashing green

Standby. The device is not communicating with the interface block. Normal state
when only power has been applied to the transceiver.

Flashing red

Connection timeout. Most often occurs when data is corrupted between
interface block and transceiver. CRC failures etc. Recommended solution is to
remove electrical noise near cabling or reduce baud rate between transceiver and
interface block.

Red

Duplicate IP address. The transceiver has an unrecoverable fault; may need
replacing.

Standard I/O

Off

Outputs inactive
Inputs inactive

Yellow

Outputs active
Inputs active

Flashing green

Outputs are idled and not faulted.

Flashing red

Output faulted
Inputs faulted

Red

Outputs forced off
Inputs unrecoverable fault

Aux Power

Off

No power is applied.

Solid green

The applied voltage is within specifications.

Solid yellow

The input power is out of specification.

RFID Port

Off

No power

Flashing green

No tag present, but communicating

Green

Communicating

Flashing red

No transceiver connected

Amber

Tag present

LED Name

LED State

Indicates

Power
Module
Status

Operation

Read/Write

Status