CIP Information Appendix B

Input Image (56RF-IN-IPS12)

Module Data

Reading the Input Image
Table of a 56RF-IN-IPD22
with a SLC-5/05

The biggest difference between the MicroLogix1400 and the SLC-5/05 is that
the SLC uses an EEM instruction instead of a MSG instruction, but the setup is
basically the same. The routing information for the EEM is stored within the
Control Block address (N30:0)

• N10:0 is the data table address where the input image will be stored and

will span N10:0 thru N10:57.

• The size in words is 58 (116 bytes).
• Service is type Read Assembly
• Class 4 is the Assembly Instance Class
• Instance 79h is the input image connection instance.
• Attribute 3 is the assembly attribute for the input image table

Word

Description

Word

Description

N20:0

Module Data

N20:6

Length

N20:1

Reserved

N20:7

Timeout

N20:2

Channel[0] Reset

N20:8…N20:9

UIDLow

N20:3

Block Size

N20:10…N20:11 UIDHi

N20:4

Command

N20:12…N10:31 Data

N20:5

Address

Bit

Definition

Bit

Definition

0

Run Mode

8

Pt00 Data

1

Reserved

9

Reserved

2

Reserved

10

Reserved

3

Reserved

11

Reserved

4

Reserved

12

Reserved

5

Reserved

13

Reserved

6

Reserved

14

Reserved

7

Reserved

15

Reserved