CIP Information Appendix B
Input Image (56RF-IN-IPD22A)
Module Status
I/O Data
Channel[n] Diagnostics
Word
Description
Word
Description
N10:0 – N10:1
Module Connection Status
N10:9
Length
N10:2
Module Status
N10:10 – N10:31 Data
N10:3
Reserved
N10:32
Channel[1] Diagnostics
N10:4
Block Status
N10:33
Command Value
N10:5
I/O Data
N10:34
Counter Value
N10:6
Channel[0] Diagnostics
N10:35
Length
N10:7
Command Value
N10:36 – N10:57 Data
N10:8
Counter Value
Bit
Definition
Bit
Definition
0
Run Status
8
Pt01 Input Fault
1
Block Fault
9
Pt01 Open Wire
2
Aux Power Fault
10
Pt01 Input Short Circuit
3
Reserved
11
Reserved
4
Pt00 Input Fault
12
Reserved
5
Pt00 Open Wire
13
Reserved
6
Pt00 Input Short Circuit
14
Reserved
7
Reserved
15
Reserved
Bit
Definition
Bit
Definition
0
Pt00 Data
8
Reserved
1
Pt01 Data
9
Reserved
2
Reserved
10
Reserved
3
Reserved
11
Reserved
4
Reserved
12
Reserved
5
Reserved
13
Reserved
6
Reserved
14
Reserved
7
Reserved
15
Reserved
Bit
Definition
Bit
Definition
0
Reset
8
Error Code
1
Fault
9
Error Code
2
Tag Present
10
Error Code
3
Busy
11
Error Code
4
Reset in Progress
12
Reserved
5
Continuous Read Mode
13
Reserved
6
Reserved
14
Reserved
7
Reserved
15
Reserved