Table 3 - LEDs

Transceiver Power Up Sequence

1.

Both LEDs OFF.

2.

Power status turns green. R/W status turns green for 0.25 seconds.

3.

R/W status turns red for 0.25 seconds.

4.

R/W status turns off for 3…5 seconds.

5.

R/W status turns amber for 0.5 seconds.

6.

R/W status turns green.

RFID Tags

RF tags come in many shapes and sizes. In general, the bigger the tag, the longer
the sensing distance from the transceiver.

Table 4

summarizes the size of the

memory for each type of tag.

Table 4 - Memory

LED Name

LED State

Indicates

Module Status

Off

There is no power applied to the block.

Green

The block is operating in a normal condition.

Red

The transceiver has an unrecoverable fault; may need replacing.

Read/Write
Status

Off

There is no power applied to the device.

Green

The EIP interface block is communicating with the transceiver, but no tag is
present. No errors received.

Amber

A tag is present within the antenna field.

Red

A communication error has occurred. Examples are: bad read/write, corrupt CRC
Note: If a read/write command is not completed while the tag is within the
field, an error will occur.

Tag Type

Total Tag
Memory

User Memory

No. of Bytes

No. of Blocks

Bytes per Block

SLI

128 B

112 B

28

4

SLI-S

256 B

160 B

40

4

SLI-L

64 B

32 B

8

4

FRAM

2048 B

2 kB

250

8