Rockwell Automation 56RF RFID System User Manual User Manual

Page 139

Advertising
background image

Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011

139

CIP Information Appendix B

Writing to the Output Image
Table of a 56RF-IN-IPD22
with a MicroLogix 1400

• N20:0 is the data table address to store the output image and will span

N20:0…N20:61.

• The number of bytes to send is 124 (62 words).
• The extended routing file (RIX12:0) is used to store the Multi-Hop

routing information.

• Service is type Write Assembly
• Class 4 is the Assembly Instance Class
• Instance 83h is the output image connection instance.
• Attribute 3 is the assembly attribute for the output image table

The Multi-Hop information is used to configure the communications path from
the MicroLogix to the RFID interface.

Advertising