SLC Code Examples

This sample code is an example using a SLC-5/05 with a Cat. No.
56RF­IN­IPD22 interface block.

Read Byte Routine

The Read Byte command (value =4) reads a user-specified number of bytes from
a tag, starting at a user-specified address. Additionally, an Option Flag can be set
to return the UUID of the tag.

• Option Flag 0

– Returns the specified user data

• Option Flag 1

– Returns the UUID of the tag and the specified user data

Note:

This command operates only on the first tag in the field.