Input only connection, Listen only connection, Class 3 connections – Rockwell Automation 56RF RFID System User Manual User Manual

Page 144

Advertising
background image

144

Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011

Appendix B CIP Information

Input Only Connection

This connection is used to read data from the module without controlling the
outputs. This connection is not dependent on any other connection.

It is recommended that the originator sets the data size in the O->T direction of
the Forward_Open be zero.

• Number of supported input only connections equals two (shared with

exclusive owner and listen only connection).

• Connection point O -> T shall be Assembly object, Instance 191 (Input

only heartbeat).

• Connection point T -> O shall be Assembly object, Instance 52, 150, or

151 (150 for product codes <= 0x100 only, 151 for product codes > 0x100
only).

Listen Only Connection

This connection is dependent on another connection to exist. If that
connection(exclusive owner or input only) is closed, the listen only connection
shall be closed as well.

It is recommended that the originator sets the data size in the Forward_Open be
zero.

• Number of supported listen only connections equals two (shared with

exclusive owner and listen only connection).

• Connection point O -> T shall be Assembly object, Instance 192 (Listen

only heartbeat)

• Connection point T -> O shall be Assembly object, Instance 52, 150 or

151 (150 for product codes <= 0x100 only, 151 for product codes > 0x100
only)

Class 3 Connections

Class 3 connections are used to establish connections to the message router. The
connection is used for explicit messaging. Class 3 connections use TCP
connections.

• Three concurrent encapsulation sessions will be supported
• Six concurrent Class 3 connections will be supported
• More than one Class 3 connection per encapsulation session will be

supported

• Supported API: 100…10000 ms
• T->O Connection type: point-to-point
• O->T Connection type: point-to-point
• Supported trigger type: application

IMPORTANT

If an exclusive owner connection has been opened against the module
and times out, the input only connection shall time-out as well. If the
exclusive owner connection is properly closed, the input only connection
shall not be affected.