Appendix B CIP Information

Instance 1 is the first input (Pt00), if the RFID interface supports two inputs,
then Pt01 would be instance 2.

The return value in CIP_Data[0] will be either 0 (Input OFF) or 1 (Input ON).

To obtain the Input Filter OffOn value of an input point, configure a CIP
message as shown below:

Instance 1 is the first input (Pt00), if the RFID interface supports two inputs,
then Pt01 would be instance 2.

The return value will contain the filter time in milliseconds.

Discrete Output Point
Object Class Code 0x0009

The following class attributes are supported:

Two instances of the Discrete Output Point Object are supported. All instances
contain the following attributes.

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

0xC1

1

2

Get

Max Instance

UINT

4 or 10

Attribute
ID

Access Rule

Name

Data Type

Value

3

Get

Value

BOOL

0 = OFF, 1 = ON

5

Get/Set

FaultMode

BOOL

0 = Use Fault Value
1 = Hold Last State

6

Get/Set

FaultValue

BOOL

0 = OFF
0 = ON

7

Get/Set

ProgMode

BOOL

0 = Use Program Value
1 = Hold Last State

8

Get/Set

ProgValue

BOOL

0 = OFF
1 = ON