EtherNet/IP Addressing

Chapter 4

5.

Change the Network Adaptor to 192.168.2.1.

Open the network connections of the host computer. Highlight the Internet
Protocol (TCP/IP) connection. Click Properties. In the IP Address field, set the
IP Address to 192.168.2.1. Click OK. Click Close to close the Local Area
Connection window (this window must be closed to apply the new address).

6.

Disable DHCP.

Click on (only once) the interface block in the Relation List to highlight it. Then
click Disable BOOTP/DHCP. This instructs the Bul. 56RF interface block to
retain the IP Address at the next power cycle.

Wait for the Status message to show that the command was successfully sent. If
not, repeat this step.