Chapter 2

RFID Components

SLI

EAS Function

The LSB of Byte 1 in Block -2 holds the EAS bit (Electronic Article Surveillance
mode active – the label responds to an EAS command)

Table 8 - EAS

EAS: e = 1 (EAS enabled) e = 0 (EAS disabled)

Application Family Identifier

The ICODE system offers the feature to use an Application Family Identifier
(AFI) at the inventory command and the two custom commands inventory read
and fast inventory read (this allows for example the creation of label families).

This 8-bit value is located at Byte 2 in Block -2 as shown in the following figure
and is only evaluated if the AFI flag is set in the reader command.

Table 9 - AFI

Data Storage Format Identifier

The Data Storage Format Identifier (DSFID) is located at Byte 3 in Block -2.

Table 10 - DSFID

Block -2, Byte 1

MSB

LSB

X

X

X

X

X

X

X

e

IMPORTANT

Changing of the EAS Configuration must be done in secure environment. The
label must not be moved out of the communication field of the antenna during
writing. We recommend to put the label close to the antenna and not to
remove it during the operation.

Block -2, Byte 2

MSB

LSB

X

X

X

X

X

X

X

X

Block -2, Byte 3

MSB

LSB

X

X

X

X

X

X

X

X

Advertising