By default, the Device Type, Vendor, and Product Code will be enabled.
Electronic keying will define how closely a replacement device must match
a failed device before the EtherNet/IP Auxiliary reconfigures a module. If
the new module does not match the criteria of one of the checked boxes,
the ADR will not function and an ADR error will appear.

3.

Once the scan list and DeviceNet module programmable parameters have
been configured, click Upload ADR Data.

The EtherNet/IP Communications Auxiliary will upload and store the
configuration data from the modules in the scan list and a confirmation
message will appear,

4.

Select Enable from the Auto Device Replace pull-down menu. This will
enable the ADR.