Limitations – Rockwell Automation 193-DNENCATR EtherNet/IP Communications Auxiliary User Manual User Manual

Page 71

Advertising
background image

Rockwell Automation Publication 193-UM014B-EN-P December 2011

71

Chapter 8

Multiple e-mail addresses can be entered into the E-mail Recipient field,
separating each e-mail address with a semicolon (;). The E-mail Recipient field is
limited to 255 characters.

Limitations

Based on the functionality of the EtherNet/IP Communications Auxiliary, there
are some limitations on when the e-mails can be triggered.

• If two events occur at the same time, an e-mail will only be sent for the

most significant error.

• If the device has been configured to send an e-mail for a lower prioritized

event and this event occurs at the same time as a higher prioritized event
for which the device has not been programmed to send an e-mail, an e-mail
will not be sent for either event.

• The Clear e-mail will only be sent when all events have been cleared and an

event e-mail has previously been sent.

EXAMPLE

An EtherNet/IP Communications Auxiliary sending an e-mail and text
message when a Communications Timeout event occurs: