Appendix B
Configuration Assembly
Table 40 - Instance 102 (Revision 1)
Byte Size
Contents
2 Bytes
Revision = 1
2 Bytes
ScanList I/O Size
2 Bytes
Data Link Update Interval (ms)
1 Byte
Data Link 1 Node
2 Bytes
Data Link 1 Parameter
1 Byte
Data Link 2 Node
2 Bytes
Data Link 2 Parameter
1 Byte
Data Link 3 Node
2 Bytes
Data Link 3 Parameter
1 Byte
Data Link 4 Node
2 Bytes
Data Link 4 Parameter
1 Byte
Data Link 5 Node
2 Bytes
Data Link 5 Parameter
1 Byte
Data Link 6 Node
2 Bytes
Data Link 6 Parameter
: : : :
: : : :
1 Byte
Data Link 48 Node
2 Bytes
Data Link 48 Parameter