Publication 1762-UM001G-EN-P - March 2011

4-6 Communication Connections

We recommend using an AIC+, catalog number 1761-NET-AIC, as your
optical isolator. See page 4-13 for specific AIC+ cabling information.

Isolated Modem Connection

Using an AIC+ to isolate the modem is illustrated below.

(1) Series C or higher cables are required.

For additional information on connections using the AIC+, refer to the
Advanced Interface Converter (AIC+) User Manual, publication
1761-UM004.

TERM

A

B

COM

SHLD

CHS GND

TX

TX

PWR

TX

DC SOURCE

CABLE

EXTERNAL

Modem Cable
(straight-through)

Personal Computer

Modem

Optical Isolator
(recommended)

Modem

MicroLogix 1200
Channel 0

Protocol Options

DF1 Full-duplex protocol (to 1 controller)

DF1 Half-duplex protocol (to multiple controllers)

Modbus RTU Slave protocol

TERM

A

B

COM

SHLD

CHS GND

TX

TX

PWR

TX

DC SOURCE
CABLE

EXTERNAL

1761-CBL-AM00 or 1761-CBL-HM02

(1)

User-supplied modem cable

Modem

MicroLogix 1200
Channel 0

24V dc
MicroLogix 1200 provides power to the AIC+ or an external power
supply may be used. See Appendix F, System Loading and Heat
Dissipation
.