Diagnostics Methods

Chapter 7

7-14

Diagnostic Counters Reset Command
Use this command to reset to zero all the diagnostic counters in the remote
station.

Command block in data table:

0005 0006 0000 0007

Response block in data table:

0000 0004 4600 1900

Table 7.F

DH Diagnostic Counters

Byte:

This counter increments when the scanner:

1

receives an ACK with a bad CRC

2

does not receive an ACK before the timeout value

3

while master, detects a message transmission by another station

(contention)

4

receives an error in the received ACK

5

adds errors in bytes 1, 2, and 4

6

receives a WAK when no receive buffer space is available at the

remote station

7

does not detect a master on the link before its timeout period expires

and so assumes mastership

8

as master, does not receive a reply from its polling sequence that has

been narrowed done to a single station

9

receives an ACK even though it does not have mastership

10

receives an illegal packet of less than 6 bytes

11

receives a packet with an incorrect destination or a packet in which the

source is equal to the destination

12

(not used)

13

receives a packet with a bad CRC

14

received a frame that was beyond the legal limit of 250 bytes

15

does not have the buffer space for a received message

16

received a message that was previously received

17

received aborted frame (line noise)

18 & 19

successfully sent a message

20 & 21

successfully received a message

22 & 23

successfully sent a command

24 & 25

successfully receives a reply

26 & 27

successfully receives command

28 & 29

successfully sends a reply

30

can not send a reply