Dh/dh+ error codes apendix b – Rockwell Automation 1775-S5_SR5,D17756.5.5 User Manual PLC-3 FAMILY I/0 User Manual

Page 170

Advertising
background image

DH/DH+ Error Codes

Apendix B

B-5

Error Code

Meaning

Associated

Commands

Error Type

124

local

all

Illegal destination in an assignment command or invalid data following a number

on a command line. For example, the lines 5 = 4 + 1 or 6ASDFGHJ generate

this error code. The line $rbWERTYUI generates error code 140 (unrecognized

command).

125

local

all

Illegal modifier for the CREATE command. Accepted modifiers for the create

command are LOCAL and GLOBAL.

126

local

all

The CREATE command was specified, but the symbol did not begin with an @.

127

local

all

$ missing in a CREATE system symbol address command line.

129

local

all

Attempt to delete nonexistent symbol.

140

local

all

Unrecognized or ambiguous command.

Channel 4 not configured for DH/DH+.

142

local

all

Illegal data following GOTO command.

143

local

all

Illegal use of label (e.g., not in a procedure).

144

local

all

Label not found.

145

local

all

Duplicate label. User symbols must be distinct from labels.

146

local

all

Too many nested procedures.

147

local

all

Insufficient privilege for the specified operation. This error can occur when an

attempt is made, via the assignment command, to write into a major section of

memory in which the scanner does not have access privileges (namely, major

section 0, 1, or 2).

148

local

all

Unbalanced parenthesis in expression.

149

local

all

A procedure name is used in a field that requires a symbolic address or a user

symbol variable.

150

local

all

A label is used in a field that requires a symbolic address or a user symbol

variable.

154

local

all

Error in reading address for symbol entry.

156

local

all

Illegal symbol in expression.

159

local

all

Bad level specified in extended address:

More than nine levels specified in an extended address.

Something other than a ( or a number followed a in an extended address.

160

local

all

Unrecognized section specifier. An illegal character followed the $ in an address.

161

local

all

Bad timer or counter specification:

The first letter of the data table address is a T, C, or P, but four characters are

not in specification. Addresses that are incorrect causing this error include

$TAC:15, $C5:3, $TACCUM:23, etc.

The key data table word specifier is four characters long and began with a T,

C, or P, but it does match the legal word specifiers (e.g., $TACM:3).

No colon following a legal word specifier.