Binary Command Language

Appendix A

A-12

When the master is ready to restart communication with the scanner:

It sends a shift in character.

The scanner echoes the shift in character and resumes communication.

If the scanner does not echo the shift in character within one character

timeout period, the master device assumes that the character is not
received, and retransmits up to a maximum of three times.

After 3 unsuccessful attempts, the master sends a CCR to the scanner

and checks the protocol fault code in the CCR response. If the fault
code is:

00 hex (no fault) or 05 hex (no input buffer available), the master

should clear its error count and retransmit the last block.

Any other fault code returns, or if the scanner does not respond to

the CCR within one character timeout period, the device should
terminate communication.

Protocol Summary

Figure A.1 summarizes the protocol used with BCL. To read this diagram:

Use the:

To see

left column

what the processor expects to receive from your device

second column

possible processor responses to your transmission

each remaining column

either

a processor response

or

the action which the processor expects your device to

take in response to its last transmission

Important: Both the processor and the external device must respond to a
break at any time. Figure A.1 shows break conditions after each
transmission, but be aware that either the processor or the external device
stops transmitting (even in the middle of a block) when it sees a break.