Chapter 7

SLC Application File

7–3

T4:0

DN

Rung 2:4
This rung simulates the temp preset value for screen #21. The operator keys in the desired temp ranging from 140 to 170.
The DTAM Plus writes this value directly to N7:21. This rung then moves the entered value to N7:20 (Data Display Register).
The data display register simulates the actual temp.

Rung 2:5
This SQO provides the bit values that simulate the Mixer (Screen #23)

SQO

SEQUENCER OUTPUT
File

#N10:80

Mask

0007

Dest

B3:0

Control

R6:2

Length

40

Position

2

T4:0

DN

( EN )
( DN )

Rung 2:3
This sequencer provides the data to simulate the %FULL of the tank (Screen #22).
There are 40 decimal values preloaded into #N10:40

SQO

SEQUENCE OUTPUT
File

#N10:40

Mask

FFFF

Dest

N7:23

Control

R6:1

Length

40

Position

2

( EN )
( DN )

MOV

MOVE
Source

N7:21

144

Dest

N7:20

144

T4:11

DN

TON

TIMER ON DELAY
Timer

T4:11

Time Base

0.01

Preset

2000

Accum

35

( EN )
( DN )

Rung 2:6
Free running timer provides variable data for Bar Graph screen #11.