Chapter 7
SLC Application File
7–4
Rung 2:7
Batch recipe free running timer.
T4:30
DN
TON
TIMER ON DELAY
Timer
T4:30
Time Base
0.01
Preset
100
Accum
22
( EN )
( DN )
Rung 2:8
Batch recipe free running timer.
T4:31
DN
TON
TIMER ON DELAY
Timer
T4:31
Time Base
0.01
Preset
500
Accum
28
( EN )
( DN )
Rung 2:9
Batch recipe free running timer.
T4:32
DN
TON
TIMER ON DELAY
Timer
T4:32
Time Base
0.01
Preset
300
Accum
14
( EN )
( DN )
Rung 2:10
When the alarm ACK bit N7:1/1 is true, the value ”0” is moved to the DTAM Plus Advisor register. This clears and resets the
alarms.
MOV
MOVE
Source
0
Dest
N7:0
0
N7:1
1
Rung 2:11
END
Ladder Logic Program