Publication 2711P-UM004B-EN-P - March 2007

16 Configure the Terminal as a Slave Device

Configure Communications

After creating your Machine Edition application, you are ready to
configure communications using RSLinx Enterprise software.

1. Open RSView Studio software.

2. In the Application Explorer dialog, double-click RSLinx

Enterprise software to expand the tree.

3. Double-click Communication Setup.

4. If prompted, select Create a New Configuration and click Finish.

5. On the Local tab, right-click the 1789-A17 Backplane icon and

select Add Device.

This is the virtual backplane of the PanelView Plus or PanelView
Plus CE device.