54 Configure the Terminal as a Scanner
Configure the Scanner Output Data
You are now ready to configure the scanner output data. You will do
this in Communications Setup in RSView Machine Edition under
RSLinx Enterprise software.
You can configure a PanelView Plus terminal as both a scanner and
slave for the same application. Add a scanner output block to the I/O
configuration. The PanelView Plus terminal will scan this output
block.
1. Right-click the Output icon to add an Address Block.
2. In the Address Block Properties dialog, set the Start Byte to 4,
Length in Bytes to 4, and click OK.
The address block 4-7 Bytes is added under Outputs.