Publication 2711P-UM004B-EN-P - March 2007
Configure the Terminal as a Slave Device 25
Create an Output Alias
To make connections to objects, aliases are required. Similar to the
input alias, you must create an alias for the output block.
1. Right-click the 0-3 Bytes icon under Output and select Add Alias.
2. In the Alias Properties dialog, select these properties and then
click OK to add the alias to the output address block:
• Alias Data Type = DINT
• Alias Name = Slave_Output
• Start Byte = 0
• Array Count = 1
• Initial Value = 0
If you do not enter an initial value, a warning message
indicates that default values will be used.