26 Configure the Terminal as a Slave Device
The slave output is now configured with the following information:
• Address length of 4 bytes, starting at byte 0.
• Slave device on node 2, which is the PanelView Plus terminal.
• Alias of Slave_Output for the output address block.
3. Click OK to save the configuration.
Create a Shortcut
The Local tab in the Communciation Setup allows the aliases you
created to be browsed from within RSView Studio software. It also lets
you to test run the application on a PC with a 1784-PCIDS DeviceNet
PCI Communication Interface card.
Create a shortcut for the PanelView Plus communication setup and
apply it the DeviceNet driver that was added to the backplane.
1. From the Communication Setup dialog click Add.
2. For this example, enter DNET as the name of the shortcut.
ATTENTION
DeviceNet network is not supported on a PC running
RSView Machine Edition software.