Preface, Who should use this manual, What is not in this manual – Rockwell Automation 7000A PowerFlex Medium Voltage AC Drive (A Frame) - ForGe Control User Manual

Page 11: General precautions

Advertising
background image

Rockwell Automation Publication 7000A-UM200C-EN-P - June 2014

11

Preface

This document provides procedural information for managing daily or recurring
tasks involving the PowerFlex 7000 medium voltage “A” Frame drives.

Who Should Use This Manual

This manual is intended for use by personnel familiar with medium voltage and
solid-state variable speed drive equipment. The manual contains material that
enables regular operation and maintenance of the drive system.

What Is Not in this Manual

This manual provides information specific to maintaining the PowerFlex 7000
“A” Frame drive. It does not include topics such as:

Dimensional and electrical drawings generated for each customer’s order

Spare parts lists compiled for each customer’s order

Human Machine Interface (HMI) operation and configuration

Please refer to the following documents for additional product detail or
instruction relating to PowerFlex 7000 “A” Frame drives:

Drive-specific Technical Data: additional troubleshooting, parameters,
and specification information for MV variable frequency drives
(

7000-TD002_-EN-P

).

Operator Interface Guide: HMI Offering with Enhanced Functionality
(

7000-UM201_-EN-P

).

For drives equipped with the PanelView 550 HMI, see
(

7000-UM151_-EN-P

).

Rockwell Automation provides the site- and installation-specific electrical and
design information for each drive during the order process cycle. If they are not
available on site with the drive, contact Rockwell Automation.

If you have multiple drive types or power ranges, ensure you have the correct
documentation for each specific PowerFlex 7000 product:

“A” Frame for lower power air-cooled configurations (up to approximately
1250 hp/933 kW)

“B” Frame for higher-power, air-cooled configurations (heat sink or heat
pipe models)

“C” Frame for all liquid-cooled configurations

General Precautions

ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts
and assemblies. Static control precautions are required when installing, testing,
servicing or repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with static control
procedures, reference Allen-Bradley publication 8000-4.5.2, “Guarding Against
Electrostatic Damage” or any other applicable ESD protection handbook.

Advertising