Component Definition and Maintenance

Chapter 3

Figure 68 - Snubber Capacitor Replacement

Figure 69 - Removing Capacitor Bank from PowerCage

5.

Remove the capacitor from the PowerCage.

6.

Place the new capacitor back into the PowerCage.

Ensure the bottom lead of the capacitor is on the stud.

7.

Slide the retaining rod into place and push the clips back into place.

8.

Connect the top lead to the capacitor.

9.

Install the PowerCage as outlined in

PowerCage Removal on page 88

.

1. Detach leads of
resistor assembly

2. Pinch and remove
clips at end of retaining
rod

3. Extract
retaining rod

Push Nut

Retaining Rod

Capacitor Bank

Advertising