Connect the leads to the resistor bank.
10.
Install the PowerCage as outlined in
.
Replacing Snubber Capacitor
The snubber capacitors are part of the capacitor assembly located behind the
PowerCage.
1.
Remove the PowerCage as outlined in
Note the connection of the leads for correct replacement.
2.
Detach the lead located on the top of the capacitor.
Figure 67 - Removal of the PowerCage
3.
Remove the push nuts on the end of the retaining rod. Pinch the clip
together and pull off. Pull out the retaining rod.
4.
Remove two bolts and swing out PowerCage plug-in stab assembly.