Replacing snubber capacitor – Rockwell Automation 7000A PowerFlex Medium Voltage AC Drive (A Frame) - ForGe Control User Manual

Page 80

Advertising
background image

80

Rockwell Automation Publication 7000A-UM200C-EN-P - June 2014

Chapter 3

Component Definition and Maintenance

9.

Connect the leads to the resistor bank.

10.

Install the PowerCage as outlined in

PowerCage Removal on page 88

.

Replacing Snubber Capacitor

The snubber capacitors are part of the capacitor assembly located behind the
PowerCage.

1.

Remove the PowerCage as outlined in

PowerCage Removal on page 88

.

Note the connection of the leads for correct replacement.

2.

Detach the lead located on the top of the capacitor.

Figure 67 - Removal of the PowerCage

3.

Remove the push nuts on the end of the retaining rod. Pinch the clip
together and pull off. Pull out the retaining rod.

4.

Remove two bolts and swing out PowerCage plug-in stab assembly.