Rockwell Automation 2711P ControlNet Communications for PanelView Plus and PanelView Plus CE User Manual

Page 39

Advertising
background image

Publication 2711P-UM003B-EN-P - March 2007

Configure Scheduled Communications 39

2. In the Connection Properties dialog, configure the producer

connection properties for the Output_to_PVP tag and click OK.

a. Set the Input Size to 2.

b. Set the Input Address and the Status Address to 0.

• The Input Size parameter (in words) must match the

Output_to_PVP tag size. Two words (a word or integer is
equivalent to a 16-bit value) equal 1 DINT (double integer or
one 32-bit value).

• The Input Address and Status Address fields are used in the

RSView Machine Edition application.

When finished, the resulting scanlist configuration screen looks
similar to this:

PV Plus CE ControlNet - Scanlist Configuration