Key-in parameters – Holtgreven GSE-375 User Manual

Page 24

Advertising
background image

18

Key-In Parameters

Key-In Parameters are not limited to a list of choices, although there may be upper and lower
value limits. A Key-In Parameter requires that a numeric value be entered using the front panel
keys. Key-In Parameters are shown with two hyphens after a decimal point within the parameter
number.

P 110.--


Indicates Parameter

Parameter Number

Denotes “Key In”

To enter a Key-In Parameter (370):

1. Press

[PRINT]. A decimal point is used to represent the entry position.

2. Press

[PRINT] until the desired character appears.

3. Press

[UNITS]. Another decimal point indicates the next entry position.

4. Repeat steps 1 and 2 until your desired entry value is shown.

5. Press

[TARE] to enter your numerical value.

To enter a Key-In Parameter (375):

1. Key in the number by using the numeric keys.

2. Press

[SELECT] to accept the entry.

To setup a full scale value of 250 lbs (370):

1.

Access the setup mode.

DISPLAY READS P110.- - ~ F.S.= ~ 100

2. Press

[PRINT] four times to select the first digit.

DISPLAY READS 2

3. Press

[UNITS] to advance to the next digit.

DISPLAY READS 2.

4. Press

[PRINT] six times to select the next digit.

DISPLAY READS 25

5. Press

[UNITS] to advance to the next digit.

DISPLAY READS 25.

6. Press

[PRINT] once to select the next digit.

DISPLAY READS 250

7. Press

[TARE] to enter the value.

DISPLAY READS P110.- - ~ F.S.= ~ 250

To setup a full scale value of 250 lbs (375):

1.

Access the setup mode.

DISPLAY READS P110.- - ~ F.S.= ~ 100

2. Key

in

250 [SELECT] to accept the entry.

DISPLAY READS P110.- - ~ F.S.= ~ 250