Activation method (independent), Changing targets from the weigh mode (independent), Example (independent) – Holtgreven GSE-375 User Manual

Page 54

Advertising
background image

48

Activation Method (Independent)

Independent Setpoints can be activated when either the gross weight, net weight or quantity (if
counting is enabled) is above or below a target value. When an independent setpoint is set to
Activate Above, the setpoint will activate when the selected mode (gross, net or quantity) is equal
to or above the target. When set to Activate Below, the selected mode must actually be below the
target.

Independent Status

Annunciator Status

Setpoint Status (Requires Setpoint Option Board)

Setpoint 1 Active

SP 1 Illuminated

Relay 1 Closed

Setpoint 2 Active

SP 2 Illuminated

Relay 2 Closed

Setpoint 3 Active

SP 3 Illuminated

Relay 3 Closed

Table 3-11: Independent Setpoint Reset (deactivation) choices

Parameter Setting

Reset Choice

Description

P51x5.0

Tare

Setpoint deactivates with [TARE].

P51x5.1

Remote Key

Do not use.

P51x5.2 Auto

Setpoint deactivates when weight returns to +/- 5 graduations of
zero and stabilizes.

P51x5.3 Non-Latched

Setpoint deactivates when weight value is in a range opposite of the
activation setting.

P51x5.4 Reset

Value

Setpoint deactivates when weigh reaches a second value and
stabilizes.



The Pre-Acts, Learn Mode, and Pause Feature options are not applicable to Independent Setpoint
operation.

Changing Targets From The Weigh Mode (Independent)

When Independent Setpoints are configured in the setpoint setup, Targ 1, 2 and 3 automatically
become available modes for the [SELECT] key. An entry followed by [TARE] or
[SAMPLE/Enter] changes the currently viewed target. If the reset for a setpoint is set to 'value',
then pressing [TARE] or [SAMPLE/Enter] alone will allow access to the subset of the target. Rtrg
1, 2 and 3 are the respective subsets for Targ 1, 2 and 3. See Changing Targets from the Weigh
Mode (General) on page 38 for detailed instructions on changing target values from the Weigh
Mode.

Example (Independent)

Setup a continuous-cycle static weighing system that fills a weigh hopper from a storage bin. The
weigh hopper should stop the fill at a predetermined target, dump the product into a bag, and
then restart the fill. A warning light should come on to give an operator advance notice to change
the bag. The following setup might be used to achieve 1000 lb dumps:

Parameter Setting

Description

P5121.1 ~ Base 1 ~ Net

Weigh hopper dump valve based on net weight.

P5122.0 ~ Act 1 ~ HI

Hopper dump valve opens when net weight rises above target 1.

P5123.-- ~ Targ 1 ~ 1000

Target 1 value = 1000 kg.

P5124.1 ~ Stbl 1 ~ Inhib

Hopper dump valve delayed until scale is stable.

P5125.2 ~ Rset 1 ~ Auto

Dump valve auto-closes when net is within +/- 5 grads of zero and stable.

P5127.1 ~ Rstb1 ~ Inhib

Dump valve closure delayed until scale is stable.

P5131.1 ~ Base2 ~ Net

Weigh hopper fill valve based on net weight.

P5132.1 ~ Act 2 ~ Under

Fill valve opens when net weight falls below target 2.

P5133.-- ~ Targ 2 ~ =100

Target 2 value = 100 kg.

P5134.1 ~ Stbl2 ~ =Inhib

Fill valve opening delayed until scale is stable.

P5135.4 ~ Rset 2 ~ =Targ

Fill valve closes when net weight reaches reset target 2.

P5136.-- ~ Rtrg2 ~ 1000

Reset target 2 = 1000 kg.

P5137.0 ~ Rstb2 ~ Ignore

Fill valve closes regardless of stability.

P5141.1 ~ Base 3 ~ Net

Alarm light relay based on net weight.

Advertising