74

S

ETUP

M

ODE

E

RRORS

Bad ~ Code!

An incorrect access code was entered

Unit ~ Seald

Access to the Setup or Calibration Mode was denied. Check the internal
"YES/NO" program jumper.

Unit3 Ntep
Code 49.

Parameter 440 (NTEP) is enabled and parameter 152 (third unit) is set to an
additional unit. The third unit is not NTEP approved.

Entry ~ Error

An invalid entry was made.

Need ~ Entry

A numeric value was required before pressing [TARE] or [SAMPLE/Enter].

Out of ~Range

The entered value exceeded the allowable range.

Can't ~ Set!

Attempt to change a parameter that does not allow an entry.

ResGT ~ 260E3
Code 35.

The number of divisions exceeds 260000 (see P110, P111).

ResGT ~ 25E3

The number of divisions exceeds 25000 (see P110, P111).

ResLT ~ 100!

The number of divisions is less than 100 (see P110, P111).

ResLT ~ 1 !!

Number of divisions is less than one (see P110, P111).

SPtxx ~ Error

A conflict occurred with a setpoint value entry (example: target entry is less than
preact). The digits 'xx' represent the last two digits of the setpoint parameter in
error (example: SPt 5 ~ Error indicates a conflict P5105, preact 1).

Prtcl ~ Error

Existing protocol is invalid. The following are not allowed:
P201 = 7 data bits, P202 = no parity, P203 = 1 stop bit

H

ARDWARE

E

RRORS

Code00

An EPROM problem detected during power up (U2).

A-D ~ Bad! Or
Code17

Problem with A/D chip detected. Disconnect any options installed and re-power
the unit. Options are connected to the same serial lines as the A/D so they may
prevent it from working properly.

Deflt ~ A-D

Bad A/D calibration values. Recalibrate A/D (see A/D Calibration Procedure on
page 77.

Re- ~ Boot!

EEPROM data could not be read. Attempting power-up reset.

Chec ~ E2

EEPROM data error (U4).

Deflt ~ Setup

An error occurred when reading setup data from the EEPROM during power-up.
All parameters are set to factory default.

Ch.XXXX A checksum error occurred during power-up. All anunciators are lit. The EPROM

integrity test failed or is improperly seated.

NoSpc ~ Free!

The current setup exceeds the setup RAM capacity.

E2 ~ Full!

The EEPROM setup exceeds the memory capacity.