Choice 7:

<STX><Unsigned DATA><sp><CR>


Choice 8:

<STX><Signed DATA><sp><lb/kg><sp><Gross/Net/Qty><STAT><SPS><CR>


Choice 9:

<STX><Signed DATA><sp><lb/kg><STAT><SPS><CR>


Choice 10:

<STX><Signed Displayed Weight><sp><lb/kg><SPS><CR>


Choice 11:

<STX><Unsigned Displayed Weight><SPS><CR>


Choice 12:

<STX><Unsigned DATA><sp><lb/kg><sp><Gross/Net/Qty><STAT><CR>

Use choice 12 to send to a 450/455/550 remote display that is set to text mode and a <CR>
terminator.

Choice 13:

<STX><Unsigned DATA><sp><lb/kg><sp><Gross/Net/Qty><STAT> <CR><LF>


Choice 14 (Simulates NCI 3835):

<LF>Signed DATA<CR><LF><STAT><CR><ETX>

Data Block Name

Description

<STX>

A single control code, decimal value of 2.

<ETX>

A single control code, decimal value of 3.

<POL>

A <space> for positive data or a - for negative data.

<Signed DATA>

8 characters right justified, space padded, including a decimal point and polarity sign.
Polarity is a ‘+’ or ‘–‘ to the immediate left of the most significant digit.

<Unsigned DATA>

8 characters right justified, space padded, including a decimal point.

<lb/kg>

Two characters indicating pounds or kilograms.

<Gross/Net/QTY>

Single word for gross weight, net weight or quantity.

<STAT>

An 'O' (overload/underload), 'M' (motion), or <space> otherwise

<SPS>

See <SPS> Setpoint Status below.

<CR>

A single control code, decimal value of 13.

<LF>

A single control code, decimal value of 10.

<sp>

ASCII Space, decimal value of 32.

<SPS> Setpoint Status

Transmitting the setpoint status will reflect the current state of all the setpoints, regardless of
which setpoint operation is configured. The status can be read as a single ASCII numeric
character (0-7), a Hex value (30h-37h) or a binary bit comparison. Status is preceded by a
<space> and an "S". The preceding data stream format is for fixed transmissions of <SPS> as
specified above. This is not associated with the custom transmission of parameter P96.

SP 1

SP 2

SP3

ASCII

Hex

Bit Comparison

Off Off Off 0

30h 0011

0000

On Off Off 1

31h 0011

0001

Off On Off 2

32h 0011

0010

On On Off 3

33h 0011

0011

Off Off On 4

34h 0011

0100

On Off On 5

35h 0011

0101

Off On On 6

36h 0011

0110

On On On 7

37h 0011

0111