Check-Weigh Status Annunciator Status

Annunciator Color (LED)

OVER

SP 1 Illuminated

Red

GOOD

SP 2 Illuminated

Green

UNDER

SP 3 Illuminated

Yellow



The Pre-Acts, Learn Mode, and Pause Feature options are not applicable to check-weigh
operation.

Changing Targets From The Weigh Mode (Absolute Check-
Weighing)

When Check-Weigh by Absolute is configured in the setpoint setup, the Targ 1 value
automatically becomes an available mode for the [SELECT] key. Keying in a value before
pressing [TARE] changes Targ 1. Targ 1 is entered as an absolute value. Pressing [TARE] or
[SAMPLE/Enter] alone gives access to the subsets. Lo and Hi are the subsets for Targ 1. Lo and
Hi are also entered as absolute values.

To change targets from the Weigh Mode:

1. Press

[SELECT].

DISPLAY READS 0.00

2. Press

[SELECT] to view the current target.

DISPLAY READS Targ1 ~ 18

3. Press

25 [TARE] or [SAMPLE/Enter] to set a new target of 25 lbs.

DISPLAY READS Targ1 ~ 25

4. Press

[TARE] or [SAMPLE/Enter] to select the low (subset) value. Key in the desired

value (example: 23.5) and press [TARE] or [SAMPLE/Enter].

DISPLAY READS Lo ~23.5

5. Press

[TARE] or [SAMPLE/Enter] to select the high (subset) value. Key in the desired

value (example: 25.75) and press [TARE] or [SAMPLE/Enter].

DISPLAY READS Hi ~ 25.75

6. Press

[SELECT] to display the current Gross Weight.

Example (Absolute Check-Weighing)

With a system set up to check-weigh 50 lb. cement bags, the following settings might be used
check-weigh bag from 49.5 to 51.5 lbs.:

Parameter Setting

Acceptable Check-Weigh Values

Comments

Target = 50.00

Desired bag weight.

Low Value = 49.50

49.50 – 50.00 lbs.

Low acceptable range = 49.50
to 50.00 lbs.

High Value = 51.50

50.00 – 51.50 lbs.

High acceptable range = 50.00
to 51.50 lbs.

I

NDEPENDENT

S

ETPOINT

O

PERATION

Independent Setpoints allow controlling setpoints when the gross, net or quantity (if counting is
enabled) is above or below a target value. The reset (deactivation) choice of each setpoint is
selectable from Tare, Remote Key, Auto, Non-latching or Absolute. See Key-In Parameters on
page 18 for instructions on using front panel keys for data entry.