Holtgreven GSE-375 User Manual

Page 65

Advertising
background image

59

3

3

0

0

0

0

S

S

e

e

r

r

i

i

e

e

s

s

C

C

o

o

m

m

m

m

a

a

n

n

d

d

C

C

o

o

d

d

e

e

s

s

It is possible to send commands through the serial port to perform specific tasks.

Table 3-17: Single Keystrokes

Hex

Decimal

Symbol

Percent
equivalent

Master /
Remote

Action

0 0

NULL

none

M

As part of an echo used to indicate character
information starting at 1

st

of 10 characters

1 1

SOH

none

M

As part of an echo used to indicate character
information starting at 2

nd

of 10 characters

2 2

STX none

M

Used to begin an echo OR as part of an echo used
to indicate character information starting at 3

rd

of 10

characters

3 3

ETX none

M

Normally to end an echo OR as part of an echo used
to indicate character information starting at 4

th

of 10

characters

4 4

EOT none

M

As part of an echo used to indicate character
information starting at 5

th

of 10 characters.

5 5

ENQ

none

M

As part of an echo used to indicate character
information starting at 6

th

of 10 characters.

6 6

ACK none

M

As part of an echo used to indicate character
information starting at 7

th

of 10 characters.

7 7

BEL none

M

As part of an echo used to indicate character
information starting at 8

th

of 10 characters.

8 8

BS none

M

Backspace OR as part of an echo used to indicate
character information starting at 9

th

of 10 characters.

9 9

HT none

M

As part of an echo used to indicate character
information starting at 10

th

of 10 characters.

A 10

LF none

M

As part of an echo used to indicate numeric display
information.

D 13

CR or
CTL-M

none M

Clear Key (clears user input or can initiate an
action). As part of an echo used to indicate
annunciator & display toggle scheme information.

11 17

CTL-Q

none

M/R

Xon

13 19

CTL-S

none

M/R

Xoff

81 129

%[Ctrl-A] M

Target

Key

85 133

%[Ctrl-E] M

Start

Key

86 134

%[Ctrl-F] M

Stop

Key

95

149

%[Ctrl-U]

M

Echo display (all 3 lines) out comm. 1

96

150

%[Ctrl-V]

M

Echo display (all 3 lines) out comm. 2

B9 185

%9

M

Enters the number before the %9 as the piece
weight

D0 208

%P

M

Pause

D0

208

%Q

M

Send out transmits one and two

D2

210

%R

M

Remote Key 2

E0 224

%’

M

Backward

Select

E3

227

%c

M

Clear Key (clears user input or can initiate an action

E5 229

%e

M

Enter

Key

E9

233

%i

M

ID Key (Print & Units on 370)

EF 239

%o

M/R

Turn

off

370

F0

240

%p

M

Print Key/ Arrow Up Key

F2

242

%r

M

Remote Key 1

F3 243

%s

M

Select

Key

F4 244

%t

M

Tare

Key

F5

245

%u

M

Units Key/ Right Arrow Key

F6 246

%v

M/R

Enter

Setup

F8

248

%x

M

[Print][Select] Keys - Extended Resolution Gross

FA 250

%z

M

Zero

Key

Advertising