Holtgreven GSE-375 User Manual

Page 31

Advertising
background image

25

P202

Parity (Comm 1) (Selection)

Select Odd, Even or None for the transmission parity.

P203

Stop Bits (Comm 1) (Toggle)

Select 1 or 2 stop bits for communication port transmissions.

P204

Comm Handshake (Comm 1) (Selection)

Select from None, Software (Xon/Xoff), Hardware (CTS/RTS), or Both.

P210

Send (Comm 1) (Selection)

Transmission Send options:

Choice Number

Selection Name

Description

P210.00

Off

All transmissions disabled.

P210.01

Press

Sends transmission with [PRINT] key.

P210.02

Cont.

Sends transmissions continuously.

P210.03

Cycle

Send single transmission after weight is reached and motion ceases. Must
return display value below 0.1% of F.S. to reset for next transmission.

P210.04

ID

Sends transmission with the stored ID.

P212

Send Stability (Comm 1) (Toggle)

Enabling Send Stability will delay any transmissions until a no-motion condition exists.

P213

Transmit Selection (Comm 1) (Selection)

Select desired print output (1 - 16 or custom). The transmission will be initiated by the selected
print operation (P210) and / or the Remote Key selection (P800). See page 29 for details on
preset formats or page 31 for details on custom transmit.

P220

Baud (Comm 2) (Selection)

Set the desired baud rate for the communication port. 150 - 115K bps

P221

Data Bits (Comm 2) (Toggle)

Select 7 or 8 data bits for the transmission.

P222

Parity (Comm 2) (Selection)

Select Odd, Even or None for the transmission parity.

P223

Stop Bits (Comm 2) (Toggle)

Select 1 or 2 stop bits for communication port transmissions.

P224

Comm Handshake (Comm 2) (Selection)

Select from None and Software (Xon/Xoff).

P230

Send (Comm 2) (Selection)

Transmission Send options:

Choice Number

Selection Name

Description

P230.00

Off

All transmissions disabled.

P230.01

Press

Sends transmission with [PRINT] key.

P230.02

Cont.

Sends transmissions continuously.

P230.03

Cycle

Send single transmission after weight is reached and motion ceases. Must
return display value below 0.1% of F.S. to reset for next transmission.

P230.04

ID

Sends transmission with the stored ID.

P232

Send Stability (Comm 2) (Toggle)

Enabling Send Stability will delay any transmissions until a no-motion condition exists.

Advertising