Holtgreven GSE-375 User Manual

Page 33

Advertising
background image

27

• Full scale capacity is always referenced from the last zero calibration reference, not the

last zero acquired by pressing [ZERO].

P412 Preset

Character

(Toggle)

If P412 is enabled, it will add a ‘P’ to the beginning of the tare parameter on the display and
transmits if the last tare value was entered manually by the user (numeric entry). P167 needs to
be enabled in order to key in a tare value. A ‘P’ will not be added if the last tare was performed by
pressing the tare key or if the tare value is zero (even if the zero value was manually entered by
the user). The ‘P’ prefix stands for “Preset”. When P412 is disabled, the unit will never show 'P'
before tare no matter how tare is entered.

P420 Display

(Selection)

Select display control option. Choose from On, Off or Auto. The auto setting helps conserve
power for extended battery life. When the Model 370/375 display is off, the load cell(s) are still
powered.

If P420 is set to Off or selection 0, you can turn on the display by holding down the [ZERO] key
upon power up.

P426 Low

Battery

Indication

(Toggle)

Press [TARE] to enable or disable this option from the gross or net modes. Low battery will be
indicated continuously if this feature is enabled without the battery option installed.

P427

Battery Option Automatic Shutdown (Selection)

Select duration of time for auto shutdown. Selections are off, 0.5, 1, 2, 3, 4, 5, 10, 15, 20, 25, 30,
35, 40, 45, and 60. Choices are in set in minutes.

P440

Legal For Trade Restrictions (Toggle)

Enable NTEP legal-for-trade restrictions. The Model 370/375 are not NTEP approved.

If P440 is enabled the following will apply:

• Serial data will not be received while in the Setup Mode.

• Received alpha characters will not be displayed.

• Numeric tare entries cannot be received through the serial port.

• Pressing [TARE] with a gross weight of zero (0) or keying in a tare value of zero (0) will

not automatically switch to the net mode.

• Negative tare values are not accepted.

• Tare rounding is enforced.

• When the tare value is zero, the net mode is not selectable.

P500

Time Setting (key in)

Enter the time in the form HH.MM.SS. Time is always shown in military format within this
parameter. P503 will determine how the time is displayed in the weigh mode.

P501

Date Setting (key in)

Enter the date in the form MM.DD.YY. P504 will determine the how the date is displayed in the
weigh mode.

Parameter
Setting

Choice

Description

P420.00

Off

Shuts off the display.

P420.01

On

Normal display operation.

P420.02

Auto

Shuts off the display when weight has stabilized within 6 divisions for 5 minutes.
Changing weight more than 6 divisions will re-enable the display. NOTE: The display
will turn back on if data is received via the RS-232 Port.