Nformation, Arameters – Holtgreven GSE-375 User Manual

Page 82

Advertising
background image

76

3. Navigate the Setup Mode as described in Setup Mode on page 16.

To exit the Setup Mode:

1. Press

[ZERO]

2. Press

[SAMPLE/Enter].

I

NFORMATION

M

ODE

P

ARAMETERS

(370

AND

375)

A series of informational parameters are available beginning at P60000. These parameters may
be accessed from the Setup Mode, or from the Weigh Mode as described below. Table 5-1 gives
an explanation of each information parameter.

To access the informational parameters:

1. Press

60000 [SELECT].

DISPLAY READS P60000 ~ E2Ins ~ 512

2. Navigate the Setup Mode as described in Setup Mode on page 16.

As each information parameter is accessed, the parameter number is briefly displayed, followed
by the parameter name, and finally the parameter value. To repeat the parameter number and
name sequence, press [SELECT]. To exit the information mode, press [ZERO].

Table 5-1: Information Parameters

PARAMETER

NAME

DESCRIPTION

60000

E2Ins

Total amount of EEPROM storage.

60001

E2Fre

Amount of available EEPROM storage.

60090

SPEEd

Set and view the microprocessor speed. The higher the speed of the
processor, the more power consumption. The default value is 3.69 MHz.
Press the [TARE]

key on the 370 or

[SAMPLE/Enter]

key on the 375 to

change the value. The value will not take affect until power is cycled. View
the current processor speed by pressing [PRINT] or [UNITS]

60100

-GSE- ~ c1998

Copyright statement.

60101

0370P ~ 01001

Firmware revision code.

60102

02- 10 ~ 1998

Firmware date code.

60200

b sn ~ 10001

Main circuit board serial number.

60201

Audit ~ Trail
Euro ~ 00000

OIML (European) audit trail number. Does not apply to the Model 370/375.

60202

i sn ~ 00000

Model 370/375 serial number.

60203

Audit ~ Trail
CAL. ~ 00000

Calibration audit trail number. Does not apply to the Model 370/375.

60204

Audit ~ Trail
Setup ~ 00000

Setup audit trail number. Does not apply to the Model 370/375.

61100

Load ~ Cell
0.00000

Current mV/V output of the load cell.

61101

Cal ~ Factr
1.00000

Calibration factor for the load cell.

61102

Rezro ~ Load
0.00000

Amount of weight (in default units) zeroed through use of the [ZERO] key.

61103

Zrtrc ~ Load
0.00000

Amount of weight (in default units) zeroed by the zero track feature since
[ZERO] was last pressed.

61104

CZero ~ 0P

Coarse zero calculated during calibration.

61105

Fine ~ Zero
1738

Fine zero calculated during calibration.

61106

CGain ~ 50

Coarse gain calculated during calibration.

61107

Fine ~ Gain
1.00000

Fine gain calculated during calibration.

61110

61112

Zero ~ Adj25
73741

Zero ~ Ad100
-21813

A/D compensation for coarse zero.

Advertising