Example (Percentage Check-Weighing)

With a system set up to check-weigh ice cream containers, the following settings might be used
to guarantee container weights from 4.95 to 5.10 lbs.:

Parameter Setting

Acceptable Check-weigh Values

Comments

Target = 5.00

Desired container weight.

Percent Lo Value = 1

5.00 * .01 (1 %) = 0.05

Low acceptable range = 4.95 to 5.00.

Percent Hi Value = 2

5.00 * .02 (2 %) = 0.1

High acceptable range = 5.00 to 5.10.

F

ILL

The fill program is used for single-speed or dual-speed filling operations. The dual-speed fill
operation allows for both a fast and a slow fill mode. During a fast-fill, setpoints 1 and 2 are
activated. During a slow-fill or single-speed fill, only setpoint 1 is activated.

Table 3-6: Setpoint Setup (Fill)

Setpoint Selection

Function

Description

P5100.2

Fill

Select Fill Setpoint Operation

P5101.--

Targ1

Final Fill Target Value

P5104.0

Based

Select between Net or Quantity

P5105.--

PA 1

Pre-Act 1 Value (Fast-to-Slow Value; 0 for Single-Speed)

P5107.0

Start 1

Setpoint Activation Method

P5109.--

PA 2

Pre-Act 2 Value (Final Cutoff)

P5110.1

Learn 2

Learn Feature for Pre-Act 2

P5114.1

PrAc 1

Pre-Act 1 Available as Subset in Weigh Mode

P5115.1

PrAc 2

Pre-Act 2 Available as Subset in Weigh Mode

P5116.1

Pause

Keypad Press invokes Pause

See Key-In Parameters on page 18 for instructions on using the front panel keys for entering
data.

Activation Method (Fill)

The fill begins with the selected activation method. The deactivation of the setpoints is automatic.
The desired target may be based on net or quantity (if counting is enabled). See Activation
Methods (General) on page 37 for activation details.

Fill Status

Annunciator Status

Setpoint Status (Requires Setpoint
Option Board)

Fast Fill

SP 1 & SP 2 Illuminated

Relay 1 and Relay 2 Contacts Closed

Dribble Fill (or Single-Speed Fill)

SP 1 Illuminated

Relay 1 Contacts Closed

Fill Done or Pause

SP 1 & SP 2 Off

Relay 1 and Relay 2 Contacts Open

Pre-Acts (Fill)

Pre-act 1 is used for dual-speed filling. Pre-act 1 specifies when the Model 370/375 should switch
from fast-fill to slow-fill. When using a single-speed device, pre-act 1 should be set to 0 from the
Setup Mode. P5114 should also be disabled to prevent pre-act 1 from appearing as a subset of
target in the Weigh Mode.

Pre-act 2 specifies the target where the final cutoff should occur, regardless of a single-speed or
dual-speed operation.



Pre-act 1 controls setpoint 2. Pre-act 2 controls setpoint 1.